Powering Critical Infrastructure

Core Solution

Secondary Fluid Network

Advanced liquid cooling distribution systems engineered for high-density AI and HPC environments. Precision-controlled thermal management that scales with your compute demands.

40%

Energy Reduction

100kW+

Per Rack Capacity

±0.5°C

Temperature Precision

99.999%

Uptime

Intelligent Cooling Management

Our secondary fluid networks combine advanced engineering with intelligent automation to deliver optimal thermal performance.

Precision Temperature Control

PID-controlled supply water temperature maintained at ±0.5°C setpoint accuracy. Multi-zone control enables different supply temperatures for mixed workload environments.

Intelligent Fluid Distribution

Variable primary flow architecture with pressure-independent control valves (PICVs) ensures design flow rates regardless of system pressure changes. Delta-T optimization prevents low-temperature differential syndrome.

Hydraulic Balancing

Automatic balancing valves and variable speed pumping eliminate manual commissioning. Real-time flow measurement and dynamic adjustment maintain optimal hydraulic performance.

Energy Efficiency

Reduce cooling energy by 40% versus air cooling through higher fluid heat capacity, free cooling economization, and waste heat recovery for building heating applications.

Comprehensive Monitoring

Network of flow meters, temperature sensors, pressure transmitters, and leak detection provides real-time visibility. Trend analysis enables predictive maintenance and capacity planning.

AI-Driven Optimization

Machine learning algorithms predict cooling demand based on IT load trends, weather forecasts, and historical patterns. Autonomous control reduces operator intervention while maximizing efficiency.

Cooling Solutions

From traditional chilled water to cutting-edge direct-to-chip cooling, we offer the right solution for every application.

Chilled Water Distribution

Primary/secondary or variable primary chilled water systems with 7-12°C supply temperatures. Optimized for traditional server loads up to 15kW/rack with air-based heat rejection.

Supply: 7-12°CDelta-T: 5-8°CCapacity: Up to 10MW

Warm Water Cooling (W+)

ASHRAE W+ class systems operating at 25-45°C supply enable free cooling 8,000+ hours annually. Supports heat reuse for district heating, achieving net-zero or energy-positive operation.

Supply: 25-45°CFree Cooling: 8000+ hrs/yrHeat Recovery: 90%+

Rear Door Heat Exchangers

Passive or active RDHx units capture 60-100% of rack heat at source. Ideal for retrofitting air-cooled facilities to support 30-50kW racks without raised floor or CRAH modifications.

Capacity: 30-50kW/cabinetNeutral Air: 100%Retrofit: No floor mods

Direct Liquid Cooling (DLC)

Cold plates attached directly to CPU, GPU, and memory with quick-disconnect manifolds. Enables 100kW+ racks for AI training clusters while reducing fan power by 80%.

Heat Flux: >100W/cm²Fan Reduction: 80%Rack Density: 100kW+

Seamless Integration

Our secondary fluid networks integrate with your existing infrastructure, building management systems, and monitoring platforms for unified control.

  • BMS/EPMS Integration
  • DCIM Compatibility
  • Modbus/BACnet Support
  • REST API Access
  • SNMP Monitoring
  • Real-time Analytics Dashboard

Ideal Applications

AI/ML Data Centers

High-density GPU clusters requiring precision cooling

HPC Facilities

Supercomputing environments with massive heat loads

Colocation

Mixed-density environments with varied cooling needs

Sustainable DCs

Heat reuse and energy recovery applications